LAKESHORE 331 TEMPERATURE CONTROLLER LABVIEW DRIVER

Message 2 of If I implement the ramp feature, the temperature rise should be constant so we tell the system how much temperature rise should be there every minute but will I have to tune different PID values to achieve this or should one set of PID values run the whole experiment from K?? At this point I don’t think the computer is communicating correctly with the temperature monitor. The complete design will save a significant amount of time and energy in sensor characterization experiments. Share buttons are a little bit lower.

Uploader: JoJogami
Date Added: 24 June 2012
File Size: 59.49 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 88455
Price: Free* [*Free Regsitration Required]

Specifications

In its temlerature it is specified something about the hyper terminal and I have some basic commands. This page location is: Hello James Thanks for the reply. Our lab mainly focuses on designing and characterizing infrared sensors. I must run another application program using HSP, I want to share the data using clipboard.

I’ve attached the VI we use to monitor pressure and temperature. Future Truck Thermoelectric System Customer: The need for the design was to provide accuracy and simplicity in conducting sensor characterization measurements. Optical isolation between output and other circuits. Tutorials and helpful information about using Labview to simultaneously control multiple devices can be found on the National Instruments webpage at http: I have kabview modes of experiment.

  DOCUCENTRE C6500 DRIVER

Software | Lake Shore Cryotronics, Inc.

I found some vi, such as txttoclp. Message 2 of Can you confirm that you have this driver installed or another?

Net graphics Sponsored Links Next 1. Message 6 of Has anybody experience with these things? Thanks for the reply. Our other computer has a PCI, which we could move over, but if there’s a way to simply control the temperature without a DAQ that would be very helpful.

If that doesn’t help, temperahure contact the manufacturer to help you further to interface with the device. Descriptor stay as GPIB:: I think this can be done using zone setting VI.

Lake Shore Software

Without having a temperature controller to try this out on, there is no way for us to know how the controller responds to these commands. By country Product registration Request a catalog Request a quote Customer survey.

Closed-loop digital PID with manual heater power output, or open loop. These types of sensors are made from materials which produce a larger amount of current when heated than traditional infrared sensors.

Only put in the effort of complex PID settings if needed.

  82801DB/DBL AC97 AUDIO CONTROLLER DRIVER

labview • View topic • Lakeshore mode temperature controller

Donald Butler Department of Electrical Engineering, The University of Texas at Arlington, Arlington, Texas Introduction This project was mainly intended to facilitate one of the major projects currently being conducted in our lab.

Butler for giving me the opportunity to work in his lab. If I implement the ramp temperatuee, the temperature rise should be constant so we tell the system how much temperature rise should be there every minute but will I have to tune different PID values to achieve this or should one set of PID values run the whole experiment from K??

I had a question about that too.

Kiril Simov Special thanks to: Message 8 of Can anybody help with this? I would also like to thank the University of Texas Arlington controlller hosting the program.

Right now, we’re choosing a setpoint for A, then watching B drift upwards and once it gets beyond 0.